Transdutor de pressão 2 fios diferencial wet/wet 420 Mid honeywell

Transdutor de Pressão 2 Fios Diferencial Wet/Wet

Techno Supply  »  Produtos  »  Honeywell  »  Transdutor de Pressão 2 Fios Diferencial Wet/Wet
Transdutor de Pressão 2 Fios Diferencial Wet/Wet
Fabricante
Transdutor de Pressão 2 Fios Diferencial Wet/Wet
Principais características

Features

• 0.5% accuracy
• 50 psid to 750 psid range
• Stainless steel
• Intrinsically safe available (2N option only)
• CE approved 

VISÃO GERAL

Description

The Model 420 DP two-wire mid range differential pressure
transmitters utilize supply voltage of 9 Vdc to 32 Vdc to produce
a two-wire 4 mA to 20mA process loop output for differential
pressure ranges of 50 psid to 750 psid. A minimum full scale accuracy
of 0.5% is achieved. Stainless steel construction ensures
durability under harsh, industrial conditions and includes zero
and span adjustments. A variety of options are available with
the Model 420 including choice of pressure adaptors and pressure
ports.  

DETALHES TÉCNICOS

Performance Specifications

Characteristic / Measure

Pressure ranges 50, 75, 100, 150, 200, 300, 500, 750 psid
Accuracy ±0.5 % full scale
Linearity ±0.25 % full scale (typical)
Hysteresis ±0.13 % full scale (typical)
Non-repeatability ±0.07 % full scale (typical)
Output (standard) 4 mA to 20 mA
Line pressure 1500 psi
Resolution Infinite

 

Environmental Specifications

Characteristic / Measure

Temperature, operating 18 °C to 82 °C [0 °F to 180 °F]
Temperature, compensated 16 °C to 71 °C [60 °F to 160 °F]
Temperature, effect, zero ±1.0 % full scale/ 38 °C [100 °F]
Temperature, effect, span ±1.0 % reading/ 38 °C [100 °F]

 

Electrical Specifications

Characteristic / Measure

Strain gage type Bonded foil
Excitation (calibration) 15 Vdc to 40 Vdc
Maximum load resistance 500 ohm
Shunt calibration data Included
Elec. termination (std) PTIH-10-6P or equiv. (Hermetic stainless)
Mating conn. (not incl) PT06A-10-6S or equiv. (AA111)

 

Mechanical Specifications

Characteristic / Measure

Media Gas, liquid
Overload-safe 1500 psi either side
Pressure port 1/8-27 NPT female (2)
Wetted parts material 17-4 PH stainless steel
Case material Stainless steel 

DOCUMENTOS
Produtos relacionados
Célula de carga Tension/Compression
Célula de carga Tension/Compression
3124
Honeywell
Ponte Amplificadora para Sensor
Ponte Amplificadora para Sensor
UV
Honeywell
Transdutor de pressão Gage/Absoluto
Transdutor de pressão Gage/Absoluto
Z
Honeywell
FALE CONOSCO
19. 3403 2300
Av. Santo Estevão, 509
Vila Rezende - 13405-249

Piracicaba, SP - Brasil
Techno Supply Importação e Exportação Ltda.
CNPJ 05.505.756/0001-06