Brasil
E.U.A
Clique para fazer sua busca
Clique para visualizar o menu
isolador de pulso 5202b pr electronics

Isolador de Pulso

Techno Supply  »  Produtos  »  PR Electronics  »  Isolador de Pulso
Isolador de Pulso
Fabricante
Isolador de Pulso
Principais características

2 channels - 2 or 4 outputs
Dual output
5-port 3.75 kVAC galvanic isolation
Cable error detection
Universal supply by AC or DC

VISÃO GERAL

Pulse isolator with safety barrier for the supply of NAMUR sensors installed in the hazardous area.
Pulse isolator with safety barrier for the detection of mechanical contacts installed in the hazardous area.
One input signal can be used on two separate outputs.
A cable error alarm can be detected on a separate output.

Mounted vertically or horizontally on a DIN rail. Up to 84 channels per meter can be mounted.

DETALHES TÉCNICOS

PR5202B1 and 5202B2 have relays with change-over contacts or open NPN collectors available in the safe area.

PR5202B4 has 4 SPST relays, which are activated simultaneously two and two, available in the safe area. Each relay can be programmed to the function N.O. or N.C.

Inputs, outputs and supply are floating and galvanically separated.

5202B is designed according to strict safety requirements and is therefore suitable for application in SIL 2 installations.

 

Environmental Conditions

Specifications range -20°C to +60°C

Calibration temperature 20...28°C

Relative humidity < 95% RH (non-cond.)

Protection degree IP20

 

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm

Weight approx. 230 g

Wire size 1 x 2.5 mm2 stranded wire

Screw terminal torque 0.5 Nm

 

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC

 

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC

 

Auxiliary supplies

NAMUR supply 8 VDC / 8 mA

Fuse 400 mA SB / 250 VAC

Max. power consumption ≤ 1.5 W (2 channels), 5202B1 and 5202B2 ≤ 2.0 W (2 channels), 5202B4

Internal consumption ≤ 1.5 W (2 channels), 5202B1 and 5202B2 ≤ 2.0 W (2 channels), 5202B4

EMC immunity influence < ±0.5%

Extended EMC immunity: NAMUR NE 21, A criterion, burst < ±1%

 

Input specifications

Sensor types NAMUR according to EN 60947-5-6 / mechanical contact

Frequency range 0...5 kHz

Pulse length > 0.1 ms

Input resistance 1 kΩ

Trig level, signal < 1.2 mA, > 2.1 mA

Trig level, cable fault < 0.1 mA, > 6.5 mA

 

Output specifications

Relay output

Max. switching frequency 20 Hz

Max. voltage 250 VRMS

Max. current 2 AAC

Max. AC power 100 VA

Max. load at 24 VDC 1 A

NPN outputs

Max. switching frequency 5 kHz

Min. pulse length > 0.1 ms

Max. load, current / voltage 80 mA / 30 VDC

Voltage drop at 25 mA / 80 mA < 0.75 VDC / < 2.5 VDC

 

Approvals

EMC 2004/108/EC

LVD 2006/95/EC

PELV/SELV IEC 364-4-41 and EN 60742

ATEX 94/9/EC DEMKO 99ATEX127186

UL UL 913, UL 508

EAC TR-CU 020/2011

EAC Ex TR-CU 012/2011 RU C-DK.GB08.V.00410

DOCUMENTOS
Produtos relacionados
Conversor de Temperatura, Loop-Powered - Isolado
Conversor de Temperatura, Loop-Powered - Isolado
3331
PR Electronics
Transmissor Programável 2 Fios
Transmissor Programável 2 Fios
5131A
PR Electronics
Indicador LCD Loop-Powered
Indicador LCD Loop-Powered
5531A
PR Electronics
FALE CONOSCO
19. 3403 2300
Av. Santo Estevão, 509
Vila Rezende - 13405-249

Piracicaba, SP - Brasil
Techno Supply Importação e Exportação Ltda.
CNPJ 05.505.756/0001-06