Key features

High accuracy, better than 0.05% of span
Slimline housing of 6 mm
Excellent EMC performance
Selectable 60 ms / 60 s response time
Pre-calibrated temperature ranges selectable via DIP-switches 

OVERVIEW

The 3113 temperature converter measures a standard Pt100, TC J and K temperature sensor, and provides an isolated active analog current and HART® signal output.
High 3 port isolation provides surge suppression and protects the control system from transients and noise.
The 3113 can be mounted in the safe area or in Zone 2 / Division 2 areas.
Approved for marine applications.

Selectable HART® mode with HART® 7 revision protocol enables extended device programming.
Selectable DIP-mode for easy configuration of more than 1000 factory calibrated measurement ranges with HART® read only feature.
The narrow 6 mm housing allows up to 165 units to be mounted per meter of DIN rail, without any air gap between units.
Wide ambient temperature range of -25...+70°C. 

TECHNICAL DETAILS

Flexibly powered by 24 VDC (±30%) via power rail or connectors.

A 60 ms fast response time with simultaneous sensor error detection when selected.

Selectable internal/external CJC.

Excellent conversion accuracy in all available ranges, better than 0.05% of span.

Meeting the NAMUR NE21 recommendations, the 3113 provides top measurement performance in harsh EMC environments.

The device meets the NAMUR NE43 standard defining out of range and sensor error output values.

A visible green LED indicates operational status of the unit and the input sensor.

All terminals are protected against overvoltage and polarity error.

High galvanic isolation of 2.5 kVAC.

Excellent signal/noise ratio of > 60 dB.

 

Environmental Conditions

Specifications range -25°C to +70°C

Storage temperature -40°C to +85°C

Calibration temperature 20...28°C

Relative humidity < 95% RH (non-cond.)

Protection degree IP20

Installation in Pollution degree 2 & measurement / overvoltage cat. II

 

Mechanical specifications

Dimensions (HxWxD) 113 x 6.1 x 115 mm

Weight approx. 70 g

DIN rail type DIN EN 60715/35 mm

Wire size 0.13 x 2.5 mm2 / AWG 26...12 stranded wire

Screw terminal torque 0.5 Nm

Vibration IEC 60068-2-6 : 2007

Vibration: 2...25 Hz ±1.6 mm

Vibration: 25...100 Hz ±4 g

 

Supply

Supply voltage 16.8...31.2 VDC

 

Isolation voltage

Test voltage 2.5 kVAC

Working voltage 300 VAC (reinforced) / 250 VAC (Zone 2, Div. 2)

 

Response time

HART mode, (0...90%, 100...10%) 60 ms...60 s, programmable

DIP mode, (0...90%, 100...10%) < 60 ms

Max. power consumption 0.7 W

Accuracy Better than 0.05% of selected range

Signal / noise ratio > 60 dB

Signal dynamics, input 23 bit

Signal dynamics, output 18 bit

EMC immunity influence < ±0.5% of span

Extended EMC immunity: NAMUR NE 21, A criterion, burst < ±1% of span

Incorrect DIP-switch setting identification 3.5 mA output; LED 0.5 s / 1 Hz

 

Input specifications

RTD input

Temperature range, Pt100 -200...+850°C

Min. measurement range (span) 10°C

Accuracy: the greater of Better than 0.05% of span or 0.1°C

Temperature coefficient: the greater of 0.02°C/°C or ≤ ±0.01%/°C

Sensor current < 150 µA

Sensor cable resistance < 50 Ω per wire

Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω

Sensor error detection Yes - selectable via DIP-switch

Broken sensor detection > 800 Ω

Shorted sensor detection < 18 Ω

TC input

Temperature range, TC J -100...+1200°C

Temperature range, TC K -180...+1372°C

Min. measurement range (span) - TC J & K 50°C

Accuracy: the greater of Better than 0.05% of span or 0.5°C

Temperature coefficient: the greater of 0.1°C/°C or ≤ ±0.01%/°C

Sensor cable resistance < 5 kΩ per wire

Cold junction compensation (CJC): Accuracy @ external Pt100 input Better than ±0.15°C

Cold junction compensation (CJC): Accuracy @ internal CJC Better than ±2.5°C

Open Thermocouple detection Yes - selectable via DIP-switch

Internal CJC error detection Yes

External CJC error detection Yes - selectable via DIP-switch

 

Output specifications

Current output

Programmable signal ranges 4...20 and 20...4 mA

Load (@ current output) ≤ 600 §Ù (23 mA)

Load stability ≤0.01% of span / 100 Ω

Common output specifications

Updating time 10 ms

Range limits 3.8...20.5 mA NAMUR NE43

Sensor error indication 3.5 mA or 23 mA / acc. to NAMUR NE43 or OFF

Open output < 20 V

HART protocol revisions HART 7

 

Approvals

EMC 2004/108/EC

RoHS 2001/695/EU

LVD 2006/95/EC

ATEX 94/9/EC KEMA 10ATEX0147 X, II 3 G Ex nA IIC T4 Gc

IECEx KEM 10.0068X

FM 3041043-C

DNV Marine Stand. f. Certific. No. 2.4

GL V1-7-2

EAC TR-CU 020/2011

UL UL 61010-1

DOCUMENTS
Related products
Universal Uni/Bipolar Signal Transmitter
Universal Uni/Bipolar Signal Transmitter
4104
PR Electronics
Temperature Converter, Loop-Powered - Isolated
Temperature Converter, Loop-Powered - Isolated
3331
PR Electronics
2-Wire Programmable Transmitter
2-Wire Programmable Transmitter
5131A
PR Electronics
CONTACT
19. 3403 2300
Av. Santo Estevão, 509
Vila Rezende - 13405-249

Piracicaba, SP - Brazil
Techno Supply Import and Export Ltda.
CNPJ 05.505.756/0001-06